Products Description
Product overview:
The ZAC60 series is a power supply that converts mains electricity into required voltage and frequency through power conversion circuits. Its key features include providing pure and reliable sine wave power output, low harmonic distortion, high-frequency stability, and voltage regulation. The system can simulate varying voltage and frequency characteristics from different regions worldwide, making it suitable for industrial production lines, quality verification, R&D applications, and other scenarios.
Product features:
● High overload capacity: power unit is modular, can withstand twice the rated current without voltage drop;
● Fast dynamic response: sudden load voltage transient change <1%, recovery time <20ms;
● Good human-computer interaction: 7-inch touch operation display with resolution of 800*480;
● Strong anti-interference: optical fiber drive control, with strong anti-electromagnetic interference and reliability;
● High protection level: the surface of the equipment cabinet is treated with electrostatic spraying, and the PCB is treated with anti-corrosion paint and resin injection.
App industries:
It can be used in various automation systems, laboratories and measurement rooms for testing the effects of various alternating current sources, and can also be used as a centralized power supply for factories and laboratories.
unit type | ZAC60 -11005 | ZAC60 -11010 | ZAC60 -11030 | ZAC60 -11050 | ZAC60 -11100 | ZAC60 -11150 | ZAC60 -11200 | ZAC60 -11300 |
power rating | 0.5KVA | 1KVA | 3KVA | 5KVA | 10kVA | 15KVA | 20KVA | 30kVA |
Input exchange indicators | ||||||||
Power supply type | Single phase two wire +PE | |||||||
voltage range | 220V(±15%) | |||||||
frequency range | 50/60Hz(±10H) | |||||||
Output AC characteristics | ||||||||
Power supply type | Single phase two wire | |||||||
voltage range | Low grade: 0~150V, high grade: 0~300V. | |||||||
Current range (low end) | 4A | 9A | 27A | 45A | 90A | 136A | 181A | 272A |
Current range (high) | 2A | 4A | 13A | 22A | 45A | 68A | 90A | 136A |
frequency range | Fixed frequency: 50/60Hz, frequency modulation: 45~65Hz | |||||||
Source effect | ≤0.1%FS | |||||||
Load effect | ≤0.1%FS | |||||||
voltage accuracy | ≤0.1%F.S | |||||||
Frequency accuracy | ≤0.01%F,S | |||||||
Voltage harmonics | ≤2W | |||||||
response time | ≤5ms | |||||||
device efficiency | ≥=90% | |||||||
overload capacity | 120%~150%,1min; 150%~200%,2s; ≥200%, immediately shut off output | |||||||
system function | ||||||||
Online adjustment function | The output voltage and frequency can be adjusted online | |||||||
Quick Settings feature | Multiple sets of output voltage and frequency can be customized | |||||||
memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||
defencive function | Input undervoltage and phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||
Display and communications | ||||||||
Local operation | digital LED | LCD display screen | ||||||
display resolution | Voltage: 0.1V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW | |||||||
Display accuracy | Voltage: 0.1%F.S, current! 0.2%F.S, frequency: 0.01%, power: 0.3%F.S | |||||||
telecommunication | No communication | RS 485/LAN | ||||||
protocol | No communication protocol | Standard Modbus RTU/Modbus TCP/IP | ||||||
Safety performance | ||||||||
compression strength | 2000Vdc/60s/ no breakdown | |||||||
insulation resistance | ≥20MQ@500Vdc | |||||||
earthing resistance | ≤100mΩ | |||||||
noise | ≤65dB(A) | |||||||
service environment | ||||||||
work environment | The ambient temperature is-20℃~45℃, and the relative humidity is 0~95%, which can work continuously for 24 hours | |||||||
cooling-down method | Fan forced air cooling | |||||||
levels of protection | IP 21 | |||||||
above sea level | No more than 5000m@>2000m reduced use | |||||||
Size (W*D*H) mm | 440-460*133 (including base) | 440*460*133 (including base) | 440*460*242 (including base) | 350*560+675 (including mobile wheels) | 400*560*B00 (including mobile wheels) | 400*660*B00 (including mobile wheels) | 500-820+1100 (including mobile wheels) | 500*820-1100 (including mobile wheels) |
unit type | ZAC60 -31100 | ZAC60 -31150 | ZAC60 -31200 | ZAC60 -31300 | ZAC60 -31450 | ZAC60 -31600 | ZAC60 -311000 |
power rating | 10kVA | 15KVA | 20KVA | 30kVA | 45KVA | 60KVA | 100KVA |
Input exchange indicators | |||||||
Power supply type | Three phase four wire +PE | ||||||
voltage range | 380V(±15%) | ||||||
frequency range | 50/60Hz(±10%) | ||||||
Output AC characteristics | |||||||
Power supply type | Single phase two wire | ||||||
voltage range | Low grade: 0~150V, high grade: 0~300V. | ||||||
Current range (low end) | 90A | 136A | 181A | 272A | 409A | 545A | 909A |
Current range (high) | 45A | 68A | 90A | 136A | 204A | 272A | 454A |
frequency range | Fixed frequency: 50/60Hz, frequency modulation: 45~65Hz | ||||||
Source effect | ≤0.1%F.S | ||||||
Load effect | ≤0.1%F.S | ||||||
voltage accuracy | ≤0.1%FS | ||||||
Frequency accuracy | ≤0.01%F.S | ||||||
Voltage harmonics | ≤2% | ||||||
response time | ≤5ms | ||||||
device efficiency | ≥=90% | ||||||
overload capacity | 120%~150%,1min; 150%~200%,2s; ≥200%, immediately shut off output | ||||||
system function | |||||||
Online adjustment function | The output voltage and frequency can be adjusted online | ||||||
Quick Settings feature | Multiple sets of output voltage and frequency can be customized | ||||||
memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
defencive function | Input undervoltage and phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
Display and communications | |||||||
Local operation | Digital LED LCD display Digital LED LCD display | ||||||
display resolution | Voltage! 0.1V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW | ||||||
Display accuracy | Voltage: 0.1%F.S, current: 0.2F.S, frequency: 0.01%, power: 0.3%F.S | ||||||
telecommunication | RS 485/LAN | ||||||
protocol | Standard Modbus RTU/Modbus TCP/IP | ||||||
Safety performance | |||||||
compression strength | 2000Vdc/60s/ no breakdown | ||||||
insulation resistance | ≥20MQ@500Vdc | ||||||
earthing resistance | ≤100mΩ | ||||||
noise | ≤65dB(A) | ||||||
service environment | |||||||
work environment | The ambient temperature is-20℃~45℃, and the relative humidity is 0~95%, which can work 24 hours continuously | ||||||
cooling-down method | Fan forced air cooling | ||||||
levels of protection | IP 21 | ||||||
above sea level | No more than 5000m@>2000m reduced use | ||||||
Size (W+DH) mm | 400*550*800 (including mobile wheels) | 400*650*800 (including mobile wheels) | 500*820+1105 (including mobile wheels) | 500*820*1105 (including mobile wheels) | 520*1160*1355 (including mobile wheels) | 520*1160*1355 (including mobile wheels) | 520*1160*1355 (including mobile wheels) |
unit type | ZAC60 -33100 | ZAC60 -33200 | ZAC60 -33300 | ZAC60 -33450 | ZAC60 -33600 | ZAC60 -33900 | ZAC60 -331000 | ZAC60 -331200 | ZAC60 -331500 |
power rating | 10KVA | 20KVA | 30kVA | 45KVA | 60kVA | 90KVA | 100KVA | 120KVA | 150KVA |
Input exchange indicators | |||||||||
Power supply type | Three phase four wire +PE | ||||||||
voltage range | 380V(±15%) | ||||||||
frequency range | 50V60Hz(±10%) | ||||||||
Output AC characteristics | |||||||||
Power supply type | Three phase four wire | ||||||||
voltage range | Low grade: 0-150Va, high grade: 0-300V | ||||||||
Current range (low end) | 30A | 60A | 90A | 136A | 181A | 272A | 303A | 363A | 454A |
Current range (high) | 15A | 30A | 45A | 68A | 90A | 136A | 151A | 181A | 227A |
frequency range | Fixed frequency: 50/60Hz, frequency modulation: 45-65Hz | ||||||||
Source effect | ≤0.19FS | ||||||||
Load effect | ≤0.19FS | ||||||||
voltage accuracy | ≤0.19FS | ||||||||
Frequency accuracy | ≤0.01%FS | ||||||||
Voltage harmonics | ≤2% | ||||||||
response time | ≤5ms | ||||||||
device efficiency | ≥90% | ||||||||
overload capacity | 120%-150%,1min; 150%-200%,2s; ≥200%, immediately shut off output | ||||||||
system function | |||||||||
Online adjustment function | The output voltage and frequency can be adjusted online | ||||||||
Quick Settings feature | Multiple sets of output voltage and frequency can be customized | ||||||||
memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||||
defencive function | Input undervoltage and phase loss protection, output overvoltage, overcurrent, overplanting, short circuit protection, internal overheating protection, etc | ||||||||
Display & Communication | |||||||||
Local operation | LCD display screen | ||||||||
display resolution | Voltage: 01V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW | ||||||||
Display accuracy | Voltage: 0.1%FS, current: 0.2MF5, frequency: 0.01%, power: 0.3%F.5 | ||||||||
Yunhe Communications | RS 485/LAN | ||||||||
protocol | Standard Modbus RTU/Modbus TCP/IP | ||||||||
Safety performance | |||||||||
compression strength | 2000Vdc/60s/ no breakdown | ||||||||
insulation resistance | ≥20MQ@500Vdc | ||||||||
earthing resistance | ≤100mQ | ||||||||
noise | ≤65dB(A) | ||||||||
service environment | |||||||||
work environment | The ambient temperature is-20℃-45℃, and the relative humidity is 0-95%, which can work continuously for 24 hours | ||||||||
cooling-down method | Fan forced air cooling | ||||||||
levels of protection | P21 | ||||||||
above sea level | No more than 5000m@>2000m reduced use | ||||||||
Size (W-D*H) mm | 500-820-1105 (including mobile wheels) | 500-820-1105 (including mobile wheels) | 520-1160-1355520-1160-1355650-1420-1470650-1420-1470|650-1420-1470|650-1420-1470|650-1420-1470 (With wheels) (With wheels) (With wheels) (With wheels) (With wheels) (With wheels) (With wheels) | ||||||
unit type | ZAC60 -332000 | ZAC60 -333000 | ZAC60 -334000 | ZAC60 -336000 | ZAC60 -338000 | ZAC60 -3310000 | ZAC60 -3312000 | ZAC60 -3316000 | ZAC60 -3320000 |
power rating | 200KVA | 300KVA | 400KVA | 600kVA | 800KVA | 1000KVA | 1200KVA | 1600KVA | 2000kVA |
Input exchange indicators | |||||||||
Power supply type | Three phase four wire +PE | ||||||||
voltage range | 380V(±15W) | ||||||||
frequency range | 50/60Hz(±10%) | ||||||||
Output transfer characteristics | |||||||||
Power supply type | Three phase four wire | ||||||||
voltage range | 0~300V- | ||||||||
current range | 303A | 454A | 606A | 911A | 1215A | 1519A | 1823A | 2431A | 3038A |
frequency range | Fixed frequency: 50/60Hz, frequency modulation: 45~65Hz | ||||||||
Source effect | ≤0.1%F.S | ||||||||
Load effect | ≤0.1%F.S | ||||||||
voltage accuracy | ≤0.1%F.S | ||||||||
Frequency accuracy | ≤0.01%F.S | ||||||||
Voltage harmonics | ≤2W | ||||||||
response time | ≤5ms | ||||||||
device efficiency | ≥90% | ||||||||
overload capacity | 120%~150W,1min; 150%~200W,2s; ≥200%, immediately shut off output | ||||||||
system function | |||||||||
Online adjustment function | The output voltage and frequency can be adjusted online | ||||||||
Quick Settings feature | Multiple sets of output voltage and frequency can be customized | ||||||||
memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||||
defencive function | Input undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||||
Display and communications | |||||||||
Local operation | LCD display screen | ||||||||
display resolution | Voltage: 0.1V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW | ||||||||
Display accuracy | Voltage: 0.1%F.S, current: 0.2%F.S, frequency: 0.01%, power: 0.3MFS | ||||||||
telecommunication | RS 485/LAN | ||||||||
protocol | Standard Modbus RTU/Modbus TCP/IP | ||||||||
Safety performance | |||||||||
compression strength | 2000Vdc/60s/ no breakdown | ||||||||
insulation resistance | ≥20MΩ@500Vdc | ||||||||
earthing resistance | ≤100mΩ | ||||||||
noise | ≤65dB(A) | ||||||||
service environment | |||||||||
work environment | The ambient temperature is-20℃~45℃, and the relative humidity is 0~95, so it can work 24 hours continuously | ||||||||
cooling-down method | Fan forced air cooling | ||||||||
levels of protection | IP 21 | ||||||||
above sea level | No more than 5000m@>2000m reduced use | ||||||||
Size (WDH) mm | 1550+850*1985 (including mobile wheels) | 1550*850*1985 (including mobile wheels) | 1910*1160 *1940 | 3100+900 2080 | 3100*900 2080 | 4900*1600 2080 | 4900*1600 2080 | 4900*1600 *2080 | 4900*1600 2080 |
The maximum customization is 8000kVA