PRODUCTS

AC test power supply

video
product name

ZAC400 series medium frequency static power supply

Model:

Power:

Energy:

Description: Product overview:The ZAC400 series is our company's latest-generation aviation ground medium-frequency power supply, specifically designed to provide 400Hz external power for civil aviation technology and military aircraft during production testing, maintenance, and servicing. Featuring multi-p

Products Description

Product overview:

The ZAC400 series is our company's latest-generation aviation ground medium-frequency power supply, specifically designed to provide 400Hz external power for civil aviation technology and military aircraft during production testing, maintenance, and servicing. Featuring multi-pulse rectification, high-performance DSP as the central processor, pure digital measurement control technology, LCD touchscreen display, sleek design, and rational structural configuration, it delivers high stability, reliability, low distortion sine wave output, fast dynamic response, and aircraft power interlock functions. The system fully meets outdoor IP55 protection rating, operates across an ultra-wide temperature range (-40℃~55℃), and exhibits excellent electromagnetic compatibility. This premium aviation ground power supply ensures safety, reliability, efficiency, and clean performance.

 

Product features:

● Output frequency range: fixed frequency 400Hz, frequency modulation 300Hz~500Hz continuously adjustable;

● Strong anti-interference: linear power supply technology, ultra-low distortion rate, ultra-low external interference;

● Product standardization: 19-inch standard rack size, or floor cabinet;

● Good heat dissipation: front/side air intake, rear air outlet, save heat dissipation space, intelligent speed adjustment design of fan, reduce noise.


App industries:

It is applied to aerospace, electronic science and technology, China Shipbuilding Industry Corporation, weapons industry and equipment research institutes, military production supporting units and other fields.


 unit type

ZAC400

-11050

ZAC400

-11100

ZAC400

-31150

ZAC400

-31300

ZAC400

-33100

ZAC400

-33300

ZAC400

-33600

 power rating

5KVA

10KVA

15KVA

30KVA

10KVA

30kVA

60KVA

Input exchange indicators

Power supply type

Single phase two wire +PE

Three phase four wire +PE

Three phase four wire +PE

 voltage range

220V(±15%)

380V(±15M)

380V(±15%)

 frequency range

50/60Hz(±10%)

Output AC characteristics

Power supply type

Single phase two wire

Single phase two wire

Three phase four wire

 voltage range

0~130V.


 current range

43A

86A

130A

260A

28A

86A

173A

 frequency range

Fixed frequency: 400Hz, frequency modulation: 300~500Hz

Source effect

0.1%F.S

Load effect

0.1%F.S

 voltage accuracy

0.1%F.S

Frequency accuracy

0.01%F.S

Voltage harmonics

2%

 response time

5ms

 device efficiency

90%

 overload capacity

120%~150%,1min; 150%~200%,2s; 200M, immediately shut off output

 system function

Online adjustment function

The output voltage and frequency can be adjusted online

Quick Settings feature

Multiple sets of output voltage and frequency can be customized

 memory function

After power failure recovery, the last output mode and parameters can be remembered

 defencive function

Input undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc

Display and communications


Local operation

Digital LED LCD display                                       Digital LED LCD display

 display resolution

Voltage: 0.1V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW

Display accuracy

Voltage: 0.1%F.S, current: 0.2MFS, frequency: 0.01%. Power: 0.3MF.S

 telecommunication

RS 485/LAN

 protocol

Standard Modbus RTU/Modbus TCP/IP

Safety performance

 compression strength

2000Vdc/60s/ no breakdown

 insulation resistance

20MΩ@500Vdc

 earthing resistance

100mΩ

 noise

65dB(A)

 service environment

 work environment

The ambient temperature is-20~45, and the relative humidity is 0~95%, which can work continuously for 24 hours

 cooling-down method

Fan forced air cooling

 levels of protection

IP 21 (standard) /IP54 (optional)

 above sea level

No more than 5000m@>2000m reduced use

Size (W*D*H) mm

350*560*675

(including mobile wheels)

400*660*800

(including mobile wheels)

500+820-1105

(including mobile wheels)

50D*820*1105

(including mobile wheels)

500*820*1105

(including mobile wheels)

520*1160*1355

(including mobile wheels)

650*1420*1470

(including mobile wheels)


Send Inquiry