Products Description
Product overview:
The HCT series is a high-precision constant current source with stable current output and low harmonic distortion. This constant current source maintains stable output current even when external power grid fluctuations occur or electrical impedance characteristics change. It is primarily used in products and testing environments requiring specific current thermal effects.
Product features:
● When using constant current and constant voltage, it can be automatically cross-transformed to maintain the characteristics of both control and protection;
● The output current is constant, the output waveform is pure sine wave, can be used as an overcurrent detection instrument;
● Can be a resistive, inductive and capacitive load, to meet the requirements of low-voltage electrical appliances for test power supply;
● High stability and high precision to ensure constant output current;
● Automatic test can be performed at different current levels, and the operation can be tested repeatedly.
App industries:
Applied in motor electronics industry, colleges and universities, laboratories and research testing, industrial and mining enterprises, electrolytic electroplating, charging equipment, aging electronic components and other fields.
unit type | HCT -31060 | HCT -31090 | HCT -31120 | HCT -31150 | HCT -31300 | HCT -31450 | HCT -311500 |
power rating | 6kVA | 9KVA | 12KVA | 15KVA | 30KVA | 45KVA | 150KVA |
Input exchange indicators | |||||||
Power supply type | Three phase four wire +PE | ||||||
voltage range | 380V(±15%) | ||||||
frequency range | 50/60Hz(±10%) | ||||||
Output AC characteristics | |||||||
Power supply type | Single phase two wire | ||||||
voltage range | Low grade: 0~15V.-, high grade: 0~30V: | ||||||
Current range (low end) | 0-400A | 0-600A | 0-800A | 0-1000A | 0-2000A | 0-3000A | 0-10000A |
Current range (high) | 0-200A | 0-300A | 0-400A | 0-500A | 0-1000A | 0-1500A | 0-5000A |
frequency range | Fixed frequency: 50/60Hz, frequency modulation: 45~65Hz | ||||||
Source effect | ≤0.19%FS | ||||||
Load effect | ≤0.196F.S | ||||||
Current accuracy | ≤0.196F.S | ||||||
Frequency accuracy | ≤0.01%F,S | ||||||
Voltage harmonics | ≤2% | ||||||
response time | ≤5ms | ||||||
device efficiency | ≥90% | ||||||
overload capacity | 120W~150%,1min; 150%~200%,2s; ≥200%, immediately shut off output | ||||||
system function | |||||||
Online adjustment function | The output current and frequency can be adjusted online | ||||||
Quick Settings feature | Multiple sets of output current and frequency can be customized | ||||||
memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
defencive function | Input undervoltage and phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
Display and communications | |||||||
Local operation | LCD display screen | ||||||
display resolution | Voltage: 0.1V, current: 0.1A, frequency: 0.1Hz, power: 0.1kW | ||||||
Display accuracy | Voltage: 0.1%F.S, current: 0.2WF.S, frequency: 0.01%, power: 0.3%F.S | ||||||
telecommunication | RS 485/LAN | ||||||
protocol | Standard Modbus RTU/Modbus TCP/IP | ||||||
Safety performance | |||||||
compression strength | 2000Vdc/60s/ no breakdown | ||||||
insulation resistance | ≥20MΩ@500Vdc | ||||||
earthing resistance | ≤100mΩ | ||||||
noise | ≤65dB(A) | ||||||
service environment | |||||||
work environment | The ambient temperature is-20℃~45℃, and the relative humidity is 0~95%, which can work continuously for 24 hours | ||||||
cooling-down method | Fan forced air cooling | ||||||
levels of protection | IP 21 | ||||||
above sea level | No more than 5000m@>2000m reduced use | ||||||
Size (W+DH) mm | 400*650*800 (including mobile wheels) | 500*820*1100 (including mobile wheels) | 500*820*1100 (including mobile wheels) | 500*820*1100 (including mobile wheels) | 520+1160*1355 (including mobile wheels) | 520+1160*1355 (including mobile wheels) | 1550*850*1985 (including mobile wheels) |